HANDILAZ AEROSOL PARTICLE COUNTER

Purpose of Participation

  • Particle counter in four size channels.

Instrument description

This compact unit has four sizing channels with sensitivities from 0.3 µm to 5.0 µm. It can store up to 500 sets of data in its memory.


 
Species Aerosol concentration and size distribution
Method Laser particle counter
Quantity primary Light scattering on particles
Quantity secondary Number of particles in size channels
Size range 0.3 µm to 5.0 µm
Temporal resolution 10 minutes
Operation No precipitation
Precision 10 %
Data availability (during campaign) Weekly
Final availability (after campaign) Three months

 

Specific remarks

  • This instrument is going to be used at the top of the mountain (c. 600 m a.s.l.) near the station in order to provide data in vertical profiles.

References

Particle Measurement Systems, USA


 

Contact Information

Head: Tomasz Petelski (IOPAS)
Members: Anna Rozwadowska (IOPAS)


 